Result Display Panels of Mech-MSR

The running results of Mech-MSR are displayed in two different panels of the user interface:

  • Result panel I: It displays the quality judgment results of an individual project.

  • Result panel II: It displays the input or output data of each Step.

Result Panel I

Result panel I is above the graphical programming workspace, where the quality judgment result (OK or NG) is displayed after the project is run.

judgment result display
  • After building the project, you need to set quality judgment rules for the project in the Output Management window and determine the measurement items to be considered. After the configuration, you need to run the project again to obtain a valid judgement result.

  • Ensure that the acceptable ranges of the measurement items selected in the Output Management window have all been set in the parameter configuration panel of the corresponding Steps.


See also

Result Panel II

Result panel II is below the data visualization window (data viewer) and mainly displays the output data of the Step.

Enable Debug Output toggle icon in the graphical programming workspace to open the Output Results panel.
result display panel

The icons and their descriptions in the Result panel II are shown in the table below.

Icon Location Description

ok result

Left status bar

The measured result is judged as okay (OK).

ng result

Left status bar

The measured result is judged as not good (NG).

profile icon

Left status bar

Cyan block with white edges, which indicates the color of profile. Click it to change the color.

profile feature point icon

Left status bar

Cyan block, which indicates the color of feature points extracted from the profile data.

show detail icon

Left status bar

In some Steps, if the Show Detail option is selected in the parameter configuration panel, the details will be displayed in red.

plane icon

Left status bar

Color of fitted lines, circles, and planes.

measured value list

Measured value

If there is a drop-down list, it indicates that the measurement item has multiple results, which are displayed by serial numbers in the drop-down list.

  • By default, all results will be displayed in the data visualization window. Select a number in the drop-down list to see the corresponding result.

  • If the measurement item is area, height, etc., hover the mouse cursor over the drop-down list, and data such as area or height corresponding to each number will be displayed in the pop-up window.

eye open icon

Right status bar

Open eye means that the input or output data will be displayed in the data visualization window. Click to turn it into blind.

eye closed icon

Right status bar

Blind eye means the output or output data will not be displayed in the data visualization window. Click to turn it into open.

pin icon

Right status bar

The gray pin indicates that the input or output data can be pinned to the Output Results panel. Click to turn it into blue.

pinned icon

Right status bar

The blue pin indicates that the input or output data has been pinned to the Output Results panel and will still be displayed after switching to another Step. Click to turn it into gray.

After you set the Corrective compensation value for the measurement items under the Communication output tab of the Output Management window, the measured values before and after compensation will be displayed in the Output Results panel, where the value before compensation will be put in parentheses.

before n after compensation

See also