Getting Started

This topic will guide you through the entire process from checking package contents to using Mech-Eye Viewer to capture images.

The diagrams are for illustrative purposes only. The actual product may differ.

1. Check Package Contents

  1. Make sure that the package is intact when you receive it.

  2. Check contents according to the “packing list” in the package to ensure that no devices or accessories are missing or damaged.

The table below is for reference only. Please take the “packing list” in the package as the final.

Camera

Accessory bag

User manual

camera package content

accessory bag

user manual

Calibration board (UHP-140 only)

DC power cable

Ethernet cable

calibration board

dc power cable

ethernet cable

  • Optional accessories:

    DIN rail power supply

    Calibration board (except for UHP-140)

    din rail power supply

    calibration board

2. Check Ports and Indicator Lights

Please refer to the following figures and tables and check the functions of the ports and indicator lights on the camera.

2.1. DEEP, LSR S, LSR L, LSR XL, PRO S, PRO M, and UHP-140

diagram general

No.

Name

Function

DC 24V port

1: GND

3: 24 VDC

2: GND

4: 24 VDC

ETH port

1: MD3_P

5: MD1_P

2: MD2_N

6: MD0_N

3: MD2_P

7: MD3_N

4: MD0_P

8: MD1_N

PWR indicator light

Off: not connected to power

Solid green: normal voltage

Solid yellow: voltage lower than 16 V or higher than 28 V

Solid red: voltage lower than 12 V

LINK indicator light

Off: not connected to network

Solid or blinking green: connected to network

SYS indicator light

Off: camera not started

Solid green: camera starting up

Blinking green: camera operating properly

Blinking yellow: unstable voltage or abnormal temperature

Blinking red: malfunctioning

SCAN indicator light

Solid green: acquiring and processing data

Off: not acquiring or processing data

2.2. NANO, NANO ULTRA, and PRO XS

diagram special
The above figure uses NANO as an example.

No.

Name

Function

PWR indicator light

Off: not connected to power

Solid green: normal voltage

LINK indicator light

Off: not connected to network

Solid or blinking green: connected to network

ETH port

1: MD3_P

5: MD1_P

2: MD2_N

6: MD0_N

3: MD2_P

7: MD3_N

4: MD0_P

8: MD1_N

DC 24V port

1: GND

3: 24 VDC

2: GND

4: 24 VDC

3. Mount the Camera

The camera can be mounted in multiple ways. Please select the mounting method appropriate for your actual situation.

To ensure satisfactory data quality, make sure the distance between the camera and the surface of the target object is within the range of therecommended working distance while meeting the requirements for field of view and the robot’s motion space.
Please prepare a wrench. For the dimensions of the mounting holes, refer to Technical Specifications.

3.1. Mount through the Camera Bracket

The camera bracket and the heat-dissipation panel (LSR S and NANO ULTRA) are attached to the back of the camera when packaged.

As shown below, tighten the two bolts with the wrench.

  • DEEP, LSR S, LSR L, LSR XL, PRO S, PRO M, and UHP-140:

    mount with bracket 1
  • NANO and PRO XS:

    mount with bracket 2
  • NANO ULTRA:

    mount with bracket 3

3.2. Mount through Threaded Holes on the Back

  • Please remove the camera bracket and heat-dissipation panel (LSR S and NANO ULTRA) before mounting.

  • When mounting LSR S and NANO ULTRA using this method, ensure that the back of the camera is in close contact with a metal surface for heat dissipation, so that the camera does not overheat and malfunction.

As shown below, use the wrench to loosely screw on the bolts in the specified order, and then fully tighten all the bolts in the specified order.

  • DEEP, LSR S, LSR L, LSR XL, PRO S, PRO M, and UHP-140:

    mount with threaded holes 1
  • NANO and PRO XS:

    mount with threaded holes 2
  • NANO ULTRA:

    mount with threaded holes 2 1

4. Mount through Threaded Holes at the Top

  • The following models provide threaded holes for mounting at the top: LSR S, LSR XL, NANO ULTRA, and UHP-140.

  • Please remove the camera bracket before mounting.

As shown below, use the wrench to loosely screw on the bolts in the specified order, and then fully tighten all the bolts in the specified order.

mount with threaded holes 3

5. Connect Cables

Please follow these steps to connect the Ethernet and power cables of the camera.

connect the camera
  • Ethernet cable: Insert the M12-A connector of the Ethernet cable into the ETH port on the camera, and insert the RJ45 connector into the Ethernet port on the IPC.

  • DC power cable: Insert the M12-A connector of the DC power cable into the DC 24V port on the camera.

When inserting the Ethernet cable and DC power cable:

  1. When inserting, align the bump in the connector with the notch in the port.

  2. Tighten the nut. The recommended tightening torque is 0.7 N·m. A gap of about 2 mm remains after the nut is fully tightened.

  • It is recommended to connect the IPC and camera directly to ensure the speed and stability of data transmission. If the IPC does not have enough Ethernet ports, please use an industrial network switch / router with a bandwidth of at least 1 Gbps.

  • Do not use network switches / routers with bandwidths below 1 Gbps or expansion hubs. Otherwise, the network connection may become unstable, and data transmission may fail.

  • Please use shielded Ethernet cable of the CAT5e or above specification.

  • When mounting the camera onto a robot arm or other mobile equipment, please fasten the DC power and Ethernet cables on the camera end properly to avoid damaging the cables or connectors due to strain.

6. DIN Rail Power Supply

  • Please prepare the AC power cable.

  • The instructions below apply to the DIN rail power supply provided by Mech-Mind. If you use your own DIN rail power supply, please refer to its user manual for connection instructions.

  • Please use a single-phase, 3-prong power outlet with protective grounding for the AC power.

din rail connection
  1. Use a flat screwdriver to loosen the screws on the terminals of the DIN rail power supply.

  2. Connect the DC power cable: Insert the two wires with the +V labels into the two +V output terminals on the DIN rail power supply, the two wires with the -V labels into the two -V output terminals, and the wire with the PE label into the ground terminal (pe).

  3. Connect the AC power cable: Insert the live wire into the L input terminal on the DIN rail power supply, the neutral wire into the N input terminal, and the ground wire into the ground terminal (pe).

  4. Use the flat screwdriver to tighten the screws on the terminals.

  • The voltage input to the camera from the DIN rail power supply should reach 24 V.

  • Please mount the DIN rail power supply inside a control cabinet.

  • The DIN rail power supply or the DIN rail should be reliably grounded. If mounting multiple DIN rail power supplies on the same DIN rail, ensure enough distance in between.

  • Please use a single-phase, 3-prong power outlet with protective grounding for the AC power.

  • Please connect the power cable last. After power is supplied, the PWR indicator light should be solid green. If not, please contact Mech-Mind.


The mounting and connection of the camera hardware is completed. The following sections will introduce how to use Mech-Eye Viewer to connect to the camera and control the camera to capture images.

7. Download and Install Mech-Eye SDK

You can download the Mech-Eye SDK installation package from Mech-Mind Download Center.

After decompressing the installation package, double-click the installer to install Mech-Eye SDK. For more information, please refer to Mech-Eye SDK Installation Guide.

8. Set IP Addresses

Before connecting to the camera, please make sure that the following IP address are unique and in the same subnet.

  • Camera IP address

  • The IP address of the IPC Ethernet port connected to the camera

Follow these steps to set the camera IP address:

  1. Double-click to open Mech-Eye Viewer.

  2. Find the camera to be connected and click setting.

  3. Set the camera IP address.

9. Connect to Camera

  1. Find the camera to be connected in Mech-Eye Viewer, and click Connect.

    connected view

If the software or firmware needs to be upgraded, the Upgrade button is displayed instead. Please click this button to perform upgrade first, and then connect to the camera.

10. Capture Images

Click single cap to perform image capturing once.

Clicking continuous cap will trigger the camera to repeatedly capture images at predetermined intervals. Click again to stop the image capturing.

Click the data types below the image capturing buttons to check the 2D image, depth map and point cloud obtained from the camera.

acquisition
For more information on image capturing and data types, please refer to Acquire and View Data.

11. Adjust Parameters

If the quality of the obtained 2D image, depth map and point cloud is not satisfactory, you can adjust the relevant parameters in the Parameters tab on the right of the software to improve data quality.

11.1. Determine Data Quality

Based on the following criteria, roughly determine the quality of the obtained data.

  • 2D image: the 2D image is not too bright or too dark; the surface features of the target object are clearly visible.

    Too dark Good Too bright

    exposure time 5

    exposure time 90

    exposure time 500

  • Depth map and point cloud: in the depth map and point cloud, the data corresponding to the target object should be complete. In the following example, the target object is the rotors.

    Point cloud of target object incomplete Point cloud of target object complete

    exposure time 3d 1

    exposure time 3d 4

11.2. Improve 2D Image Quality

  1. Set the Exposure Mode parameter in the 2D Parameters category to Timed, and then adjust the Exposure Time parameter.

    • If the 2D image is too dark, increase Exposure Time.

    • If the 2D image is too bright, decrease Exposure Time.

      DEEP and LSR series provide two types of 2D images corresponding to different parameters. For detailed information, please refer to Parameters of DEEP Series and Parameters of LSR Series.
  2. Capture images again and check the quality of the 2D image.

11.3. Improve Quality of Depth Map and Point Cloud

  1. Adjust the Exposure Time parameter in the 3D Parameters category.

    • If the object is dark-colored or not reflective, increase Exposure Time.

    • If the object is light-colored or reflective, decrease Exposure Time.

  2. Capture images again and check the quality of the depth map and point cloud.


For more explanations of the parameters, please refer to Parameter Reference Guide.

12. Use Data

The 2D image, depth map and point cloud obtained through Mech-Eye Viewer can be saved locally or can be output to Mech-Vision or third-party machine vision software for subsequent processing and calculation.

  • Save the data: Click save in the data acquisition area, set the destination path, check the data types to be saved, and then click Save.

  • Use the data in Mech-Vision: Please refer to Vision System Tutorial and learn how to build the entire vision system that includes Mech-Vision.

  • Use the data in third-party machine vision software: The data obtained by the camera can be transmitted to third-party software through Mech-Eye API or the GenICam interface.

We Value Your Privacy