Could Not Connect to Camera

Symptom

The camera to which you want to connect could be discovered by Mech-Eye SDK or the GenICam client, but could not be connected.

Possible Causes

The reason that the camera could not be connected can be any of the following, and these reasons need to be investigated one by one:

  • The camera is connected to a router with an Ethernet cable, and the computer is connected to the Wi-Fi of the router.

  • The camera IP address and the IP address of the computer Ethernet port connected to the camera are not in the same subnet.

  • In the same local network, another device has the same IP address as the camera (IP address conflict).

  • The IP addresses of multiple computer Ethernet ports are in the same subnet.

Solutions

The instructions in this section are only applicable to the Windows operating system. If you are using the Ubuntu operating system, please contact Technical Support.

Please investigate each of the above reasons one by one according to the following sections.

Computer Connected to Router Wi-Fi

Please follow these steps to troubleshoot the issue:

  1. Open the Control Panel and select View network status and tasks under Network and Internet.

  2. Check if Wi-Fi is displayed next to Connections.

    • If so, proceed to step 3.

    • If not, proceed to the next section.

  3. Disable the Wi-Fi function of the router or connect the router and computer with an Ethernet cable. Then, check if the camera can be connected in Mech-Eye SDK or the GenICam client.

    • If so, the troubleshooting is completed.

    • If not, proceed to the next section.

Camera IP address and IP Address of Computer Ethernet Port Not in the Same Subnet

Please follow these steps to troubleshoot the issue:

  1. Check the camera IP address in Mech-Eye Viewer.

  2. Refer to Set IP Address on Computer and check the IP address of the computer Ethernet port connected to the camera.

    • If the computer Ethernet port is set to Obtain an IP address automatically, refer to Set IP Address on Computer and set a static IP address for the Ethernet port. Then, proceed to step 3.

    • If the two IP addresses are not in the same subnet, modify the IP address of the camera or the computer Ethernet port so that the two are in the same subnet. Then, proceed to step 3.

      Modify the camera IP address

      Use Mech-Eye Viewer or the IP configuration tool to modify.

      Modify the IP address of the computer Ethernet port

      Refer to Set IP Address on Computer.

    • If the two IP addresses are in the same subnet, proceed to the next section.

  3. Check if the camera can be connected in Mech-Eye SDK or the GenICam client.

    • If so, the troubleshooting is completed.

    • If not, proceed to the next section.

IP Address Conflict

Please follow these steps to troubleshoot the issue:

  1. Disconnect the computer from devices other than the camera, including devices connected through a network switch / router.

  2. Check if the camera can be connected in Mech-Eye SDK or the GenICam client.

    • If so, another device has the same IP address as the camera. Proceed to step 3.

    • If not, proceed to the next section.

  3. Connect one of the other devices to the computer, and then check if the camera can be connected in Mech-Eye SDK or the GenICam client. Then, disconnect that device. Repeat this process until you find the device whose connection makes the camera not connectable. This is the device that has the same IP address as the camera.

  4. Modify the IP address of this device, or modify the camera IP address with Mech-Eye Viewer or the IP configuration tool. Then, connect the other devices to the computer.

  5. Check again if the camera can be connected in Mech-Eye SDK or the GenICam client.

    • If so, the troubleshooting is completed.

    • If not, proceed to the next section.

IP Addresses of Multiple Computer Ethernet Ports in the Same Subnet

Please follow these steps to troubleshoot the issue:

  1. Disable the Ethernet ports other than the one connected to the camera:

    1. Open the Control Panel and select View network status and tasks under Network and Internet.

    2. Select Change adapter settings on the left. The Network Connections window will pop up.

    3. In the Network Connections window, right-click the Ethernet ports other than the one connected to the camera and select Disable.

  2. Check if the camera can be connected in Mech-Eye SDK or the GenICam client.

    • If so, then the IP addresses of multiple computer Ethernet ports are in the same subnet. Proceed to step 3.

    • If not proceed to step 4.

  3. Modify the IP addresses of the disabled Ethernet ports and then enable these Ethernet ports:

    1. Return to the Network Connections window, and refer to Set IP Address on Computer and modify the IP addresses of the disabled Ethernet ports to other subnets.

    2. Right-click these Ethernet ports and select Enable to enable these Ethernet ports. Then, check if the camera can be connected in Mech-Eye SDK or the GenICam client.

      • If so, the troubleshooting is completed.

      • If not proceed to step 4.

  4. Restart the camera: Disconnect the camera from power and then reconnect it to power. Then, check again if the camera can be connected in Mech-Eye SDK or the GenICam client.

    • If so, the troubleshooting is completed.

    • If not, please contact Technical Support.