DIN Rail Power Supply
In the 24 VDC power supply solution, the power module consists of the camera’s DC power cable and a DC power supply device (such as a DIN rail power supply). For the DC power supply device, it is recommended to use the DIN rail power supply provided by Mech-Mind. You may also choose other DIN rail power supplies or DC power devices that comply with the relevant safety standards.
This article introduces the technical specifications and usage notes of the DIN rail power supply provided byMech-Mind.
|
Technical Specifications of DIN Rail Power Supply
The following table lists the technical specifications of the DIN rail power supply provided by Mech-Mind.
Model | NDR-120-24 | EDR-120-24 (India only) | |
---|---|---|---|
Output |
DC voltage |
24 V |
24 V |
Rated current |
5 A |
5 A |
|
Rated power |
120 W |
120 W |
|
Input |
Voltage range |
90–264 VAC |
90–264 VAC |
Frequency range |
47–63 Hz |
47–63 Hz |
|
AC current |
2.25 A/115 VAC
|
2.25 A/115 VAC
|
|
Max inrush current |
20 A/115 VAC
|
20 A/115 VAC
|
|
Leakage current |
< 1 mA/240 VAC |
< 1 mA/240 VAC |
|
Protection |
Overload |
105–130% rated output power |
|
Protection type: Constant current mode, recovers automatically after fault condition is removed |
|||
Over voltage |
29–33 V |
29–33 V |
|
Protection type: Shut down output voltage, re-power on to recover |
|||
Over temperature |
Shut down output voltage, re-power on to recover |
||
Environment |
Operating temperature |
-20–70°C |
-20–60°C |
Operating humidity |
20–95%RH, non-condensing |
20–95%RH, non-condensing |
|
Storage temperature |
-40–85°C |
-40–85°C |
|
Storage humidity |
10–95%RH, non-condensing |
10–95%RH, non-condensing |
Usage Notes
-
Please mount the DIN rail power supply inside a control cabinet.
-
The DIN rail power supply or the DIN rail should be reliably grounded. If mounting multiple DIN rail power supplies on the same DIN rail, ensure enough distance in between.
-
When connecting the cables to the DIN rail power supply, please follow the labels on the cables for proper connection. The wire core colors may vary between different batches of cables.
-
Ensure that all cables are connected before powering on the laser profiler. After power is supplied, the controller’s PWR indicator light should be solid green. Otherwise, please contact Mech-Mind Technical Support.
-
When using a DIN rail power supply to power the controller, ensure a one-to-one configuration, meaning one DIN rail power supply is connected to one controller, to ensure stable power for the controller.
-
Please correctly route and wire cables according to Cable Routing and Wiring Guidelines for Laser Profiler.