Modbus TCP–Siemens SIMATIC S7 PLC Functions

You are viewing an old version of the documentation. You can switch to the documentation of the latest version by clicking the top-right corner of the page.

This topic introduces the functions for Modbus TCP communication between a Siemens SIMATIC S7 PLC using the TIA Portal software and Mech-Mind Software Suite. For the detailed register map table, refer to Register Map.

Function Descriptions

Start Mech-Vision Project

This function is used for applications that use Mech-Vision but not Mech-Viz. This function starts the Mech-Vision project that executes image capturing and performs vision recognition.

start mech vision 1

Parameters

Input Parameters

  • Vision_Proj_Num: Mech-Vision project ID, which is the number before the project name in the Project List panel in Mech-Vision.

  • Robot_Pose_Type: The type of robot pose to input to Mech-Vision. The value range is 0 to 3.

  • Robot_Pose: The pose received from the robot, value depends on the value of Robot_Pose_Type. Data type: two-dimensional array [0..1, 0..5] of Real, array[0] is joint positions and array[1] is flange pose.

The following table explains the relationship between Robot_Pose_Type and Robot_Pose.

Robot_Pose_Type value Robot_Pose value Description Applicable Scenarios

0

0, 0, 0, 0, 0, 0 0

No need to input robot pose to Mech-Vision.

Project is in the Eye-to-Hand mode. If the “Path Planning” Step is used in the Mech-Vision project, the planned path starts at the Home point set in the path planning tool.

1

Current joint positions and flange pose of the robot

Robot joint positions and flange pose must be input to Mech-Vision.

Project is in the Eye-In-Hand setup. Applicable to most robots (excluding truss robots).

2

Current flange pose of the robot

Robot flange pose must be input to Mech-Vision.

Project is in the Eye-In-Hand setup. The robot has no joint positions and only flange pose (such as truss robots).

3

Joint positions of the start point of the planned path

The joint positions of the path start point must be input to Mech-Vision.

Project is in the Eye-In-Hand setup and the Mech-Vision project contains the “Path Planning” Step, whose start point needs to be set from the robot side.

  • Start_Vision: Trigger the start of the Mech-Vision project at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 1102 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

start mech vision 2

Example Description

When “Camera_User”.Start_Vis is at the rising edge, this example runs Mech-Vision project No.1, asks the Mech-Vision project to send over 1 vision point, and sends the robot joint positions when the Mech-Vision project is started as the image-capturing pose to Communication Component.

Get Vision Target(s)

This function is used for applications that use Mech-Vision but not Mech-Viz. It obtains the vision result from the corresponding Mech-Vision project.

get mech vision data 1

Parameters

Input Parameters

  • Vision_Proj_Num: Mech-Vision project ID, which is the number before the project name in the Project List panel in Mech-Vision.

  • Get_VisData: Obtain vision points from Mech-Vision project when a rising edge occurs.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 1100 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

  • Status of Pose Sent: 1 represents that the pose data written in are new. After the PLC reads the pose data, please run the MM_Empty_Target FB to reset the register to 0.

  • Number of Pose Sent: Store the number of vision points sent by Mech-Vision, from 1 to 20.

  • Target Pose: Store the waypoint poses sent by Mech-Vision as TCPs.

  • Target Label: Store the integer labels corresponding to the poses. Labels are set in Mech-Vision.

Example

get mech vision data 2

Example Description

When “Camera_User”.Get_VisData is at the rising edge, this example obtains the vision result from Mech-Vision project No.1.

Switch Mech-Vision Recipe

This function specifies which parameter recipe of the Mech-Vision project to use. Parameter recipes can be used to switch parameter settings, including point cloud model for matching, ROI, confidence threshold, etc, in the same Mech-Vision project when it is used to recognize different workpieces. This function must be called BEFORE MM_Start_Vis.

set formula 1

Parameters

Input Parameters

  • Vision_Proj_Num: Mech-Vision project ID, which is the number before the project name in the Project List panel in Mech-Vision.

  • Vision_Recipe_Num: The ID of a parameter recipe in the Mech-Vision project, from 1 to 99.

  • Switch_Recipe: Switch the parameter recipe when a rising edge occurs.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 1107 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

set formula 2

Example Description

When “Camera_User”.Switch_Recipe is at the rising edge, this example switches the parameter recipe used to No.2 in Mech-Vision project No. 1.

Get Result of Step “Path Planning” in Mech-Vision

After calling MM_Start_Vis, call this function to obtain the collision-free picking path planned by the “Path Planning” Step in the Mech-Vision project.

When using this function, set the Port Type parameter of the “Procedure Out” Step in the Mech-Vision project to “Predefined (robot path)”.

Before executing this function, please set Req_Pose_Num in MM_Start_Vis to 0 to reduce the times of execution of this function. If Req_Pose_Num in MM_Start_Vis is set to 1, then every time this function is executed, only 1 waypoint is returned, and this function must be executed multiple times to obtain all the waypoints.
get planned visdate 1

Parameters

Input Parameters

  • Vision_Proj_Num: Mech-Vision project ID, which is the number before the project name in the Project List panel in Mech-Vision.

  • Request_Pose_Type: Specify the type of waypoint pose returned by the “Path Planning” Step, 1 or 2.

    • 1: The waypoint poses are returned in the form of joint positions (JPs).

    • 2: The waypoint poses are returned in the form of tool center point (TCP).

The Request_Pose_Type here and the Robot_Pose_Type in the MM_Start_Vis and MM_Start_Viz FBs all correspond to the same Pose Type label in the MM Modbus TCP Interface data block. Therefore, if these parameters are set to different values, the programming should ensure that the two values do not take effect at the same time.
  • Get_VisData: Obtains the planned path from the “Path Planning” Step in Mech-Vision at the rising edge.

  • Set_Edge: Store the value of Get_VisData in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status_Code: If there is no error, status code 1103 will be returned. Otherwise, the corresponding error code will be returned.

  • Status of Pose Sent: 1 represents that the pose data written in are new. After the PLC reads the pose data, please run the MM_Empty_Target FB to reset the register to 0.

  • Number of Pose Sent: Store the number of received waypoints sent by Mech-Vision, from 1 to 20.

  • Index of Vision Move: Store the position of the Vision Move waypoint in the path.

  • Target_Pose: Store the received waypoint poses in the form of joint positions or the XYZ Euler angles, depending on the input parameter Request_Pose_Type.

  • Target Label: Store the integer labels corresponding to the poses. Labels are set in Mech-Vision.

  • Speed_Percentage: Store the velocity settings corresponding to the poses.

Example

get planned visdate 2

Example Description

When there is a rising edge on the variable Camera_User.Get_VisData, the path planned by the Mech-Vision project No.1 will be obtained in the form of joint positions.

Start Mech-Viz Project

This function is for applications that use both Mech-Vision and Mech-Viz. It runs the corresponding Mech-Viz project (which triggers the corresponding Mech-Vision project to run), and then plans the path for picking.

start mech viz 1

Parameters

Input Parameters

  • Robot_Pose_Type: The type of robot pose to input to Mech-Viz. The value range is 0 to 2.

  • Robot_Pose: The pose received from the robot, value depends on the value of Robot_Pose_Type. Data type: two-dimensional array [0..1, 0..5] of Real, array[0] is joint positions and array[1] is flange pose.

The following table explains the relationship between Robot_Pose_Type and Robot_Pose.

Robot_Pose_Type value Robot_Pose value Description Applicable Scenarios

0

0, 0, 0, 0, 0, 0

No need to input the robot pose to Mech-Viz. The simulated robot in Mech-Viz moves from the initial pose JPs = [0, 0, 0, 0, 0, 0] to the first waypoint.

Project is in the Eye-to-Hand mode. This setting is not recommended.

1

Current joint positions and flange pose of the robot

Robot joint positions and flange pose must be input to Mech-Viz. The simulated robot in Mech-Viz moves from the input JPs to the first waypoint.

This setting is recommended for projects in the Eye-In-Hand setup.

2

Specific joint positions of the robot

The robot joint positions of a point determined by teaching must be input to Mech-Viz. The input joint positions are used to trigger Mech-Viz to plan the next path in advance while the robot is not in the camera capture region, as shown below. The simulated robot in Mech-Viz moves from the input joint positions to the first waypoint.

This setting is recommended for projects in the Eye-to-Hand mode.

The reason for setting robot pose type to 2 when the project is in the Eye-to-Hand mode: In the Eye-to-Hand mode, the camera can perform image capturing for the next round of path planning before the robot returns to the camera capture region and picking region, shortening the cycle time. If Robot_Pose_Type is set to 1, the robot’s current pose is sent to Mech-Viz. The simulated robot will move from the input pose to the first waypoint in the planned path, while the real robot might move to another point first, and then move to the first waypoint. Therefore, the path of the real robot may contain unpredicted collisions, leading to safety hazards. In conclusion, Robot_Pose_Type should be set to 2 for projects in the Eye-to-Hand setup.

robot example
  • Start_Viz: Triggers the Mech-Viz project to run at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2103 is returned if Mech-Viz is successfully started and no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

start mech viz 2

Example Description

When the variable * “Camera_User”.Start_Viz* is at the rising edge, this example runs the corresponding Mech-Viz project, and sends the current joint positions of the robot to Communication Component.

StopMech-Viz Project

This function stops the execution of the Mech-Viz Project. This function is only needed if the Mech-Viz project falls into an infinite loop or cannot be stopped normally. This function is only needed if the Mech-Viz project falls into an infinite loop or cannot be stopped normally.

stop mech viz 1

Parameters

Input Parameters

  • Stop_Viz: Stop the execution of the Mech-Viz project at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2104 is returned if Mech-Viz is successfully stopped and no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

stop mech viz 2

Example Description

When “Camera_User”.Stop_Viz is at the rising edge, this example stops the execution of the Mech-Viz project.

Select Mech-Viz Branch

This function is used to select along which branch the Mech-Viz project should proceed. Such branching is achieved by adding Branch by Msg Step(s) to the project. MM_START_VIZ must be called BEFORE this function. When the next Step to be executed in Mech-Viz is a Branch by Msg Step, the system will wait for this function to send the exit port number by the Command 203.

set branch 2

Parameters

Input Parameters

  • Branch_Name: Step ID of the Branch by Msg Step, which is a positive integer.

  • Branch_Exit_Port: The number of the exit port to take, from 1 to 99.

    Add 1 to the port number displayed in Mech-Viz. E.g., value 1 corresponds to exit port 0 in Mech-Viz.
  • Set_Branch: Set the branch to take at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2105 is returned if the branch is successfully selected and no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

set branch 3

Example Description

When “Camera_User”.Set_Branch is at the rising edge, this example tells Mech-Viz to take exit port 1 for the Branch by Msg Step whose Step ID is 1.

Set Move Index

This function sets the value for the Current Index parameter of Steps. Steps that have this parameter include Move by List, Move by Grid, Custom Pallet Pattern, and Smart Pallet Pattern. MM_Start_Viz must be called BEFORE this function.

set index 2

Parameters

Input Parameters

  • Index_Name: Step ID of the Step with the index parameter, which is a positive integer.

  • Index_Counter: The index value that should be set the next time this Step is executed. When this function is sent, the current index value in Mech-Viz will become the parameter value minus 1. When the Mech-Viz project runs to the Step specified by this function, the current index value in Mech-Viz will be increased by 1 to become the parameter’s value.

  • Set_Index: Trigger signal to set the index. The rising edge does the trigger.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2106 is returned if the index is successfully set and no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

set index 3

Example Description

When “Camera_User”.Set_Index is at the rising edge, this example sets the Current Index value to 3 for the Step in the Mech-Viz project whose Step ID is 5. When the Step is executed, the Current Index value will be added 1 and become 4.

Get Planned Path

This function obtains the planned path from Mech-Viz.

get mech viz date 1

Parameters

Input Parameters

  • Request_Pose_Type: Specify the type of waypoint pose returned, 1 or 2.

    • 1: Mech-Viz sends waypoints in joint positions.

    • 2: Mech-Viz sends waypoints in TCPs.

The Request_Pose_Type here and the Robot_Pose_Type in the MM_Start_Vis and MM_Start_Viz FBs all correspond to the same Pose Type label in the MM Modbus TCP Interface data block. Therefore, if these parameters are set to different values, the programming should ensure that the two values do not take effect at the same time.
  • Get_VizData: Obtains the planned path from Mech-Viz at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2100 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

  • Status of Pose Sent: 1 indicates that the pose data written in are new. After the PLC reads the pose data, please run the MM_Empty_Target FB so that Communication Component will reset the register to 0.

  • Number of Pose Sent: Store the number of waypoints received from Mech-Viz, from 1 to 20.

  • Index of Vision Move: Store the position of the Vision Move waypoint in the path.

  • Target Pose: Store the received waypoint poses in the form of joint positions or the XYZ Euler angles, depending on the pose type set by Command 205.

  • Target Label: Store the integer labels corresponding to the poses. Labels are set in Mech-Vision.

  • Speed Percentage: Store the velocity settings corresponding to the poses.

Example

get mech viz date 2

Example Description

When “Camera_User”.Get_VizData is at the rising edge, this example obtains the planned path from Mech-Viz in the form of TCPs.

Get DO Signal List

This function obtains the planned DO Signal list for controlling multiple sections of a sectioned vacuum gripper. MM_Get_VizData must be called BEFORE this function.

Please refer to the suction_zone.viz template in XXXX/Communication Component-xxx/tool/viz_project/suction_zone, and set the suction cup configuration file before calling the function.
get do list 1

Parameters

Input Parameters

  • Get_DoList: Obtain the planned DO signal list from Mech-Viz at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2102 is returned if the DO signal list is successfully obtained and no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

  • DO_LIST: The list of 64 DO values, in the range of 0 to 999, with -1 being the placeholder value.

Example

get do list 2

Example Description

When “Camera_User”.Get_DoList is at the rising edge, this example obtains the planned DO signal list from Mech-Viz and stores it in the DO_LIST variable.

Input Object Dimensions to Mech-Vision

This function inputs object dimensions to the Mech-Vision project.

read object dimensions 2

Parameters

Input Parameters

  • Vision_Proj_Num: Mech-Vision project ID, which is the number before the project name in the Project List panel in Mech-Vision.

  • External_Input_Box_Dimension: Input the object’s length, width, and height in mm.

  • Set_Box_Dimension: Inputs the object dimensions in the Mech-Vision project dynamically at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 1108 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

read object dimensions 3

Example Description

When “Camera_User”.Set_Box_Dimension is at the rising edge, this example sets the object dimensions in the Read Object Dimensions Step in the Mech-Vision project No.1 to the values in External_Input_Box_Dimension.

Input TCP to Mech-Viz

This function is used to dynamically input the pose data and should be used in conjunction with the External Move Step in Mech-Viz. This function must be executed BEFORE MM_Start_Viz.

Refer to the outer_move.viz project in XXXX/Communication Component-xxx/tool/viz_project/outer_move, and put the External Move Step at a proper position in the workflow.
set pose 1

Parameters

Input Parameters

  • External_Input_Pose: TCP of the robot in mm.

  • Set_Input_Pose: Input the TCP data to the External Move Step at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 2107 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

set pose 2

Example Description

When “Camera_User”.Set_Input_Pose is at the rising edge, this example sends the pose data stored in External_Input_Pose[0–5] to the External Move Step in the Mech-Viz project.

Get Software Status

This function is currently capable of checking whether Mech-Vision ready to run projects. In the future, this function can be used for obtaining the execution status of Mech-Vision, Mech-Viz, and Communication Component.

get software state 1

Parameters

Input Parameters

  • Get_Status: Check whether Mech-Vision is ready to run projects at the rising edge.

  • Set_Edge: Store the value of Start_Vision in the last cycle to prevent unnecessary repetition of triggering.

Returned data in the MM Modbus TCP Interface DB:

  • Status code: Represent the software status.

Example

get software state 2

Example Description

When “Camera_User”.Get_Status is at the rising edge, this example checks the status code and stores it in the Status Code variable.

Clear Target Data

This function clears the obtained data stored in the Target Pose, Target Label and Speed Percentage variables.

clear target data 1

Parameters

Input Parameters

  • Start_Empty: Clear the data stored in Target Pose, Target Label, Speed Percentage at the rising edge.

  • Target_Pose: Obtained target poses.

  • Target_Label: Obtained label.

  • Speed_Percentage: Obtained velocity settings.

Returned data in the MM Modbus TCP Interface DB:

  • Status Code: 3103 is returned if no error occurred. For other values, please refer to Status Codes and Troubleshooting for the corresponding error.

Example

clear target data 2

Example Description

When the value of “Camera_User”.Start_Empty is set to 1, the data stored in the Target Pose, Target Label and Speed Percentage variables in the MM Modbus TCP Interface DB are cleared.

Appendix

Description of the Status Codes

Please refer to Status Codes and Troubleshooting for detailed information.