This guide introduces how to setup master-control communication for a DENSO robot.

Preparation

Check Controller and Software Versions

  • Controller model: RC8, RC8A, or RC9

  • Controller software: 2.15.0 (other versions unknown)

    Click here for instructions
    1. Press Setting  System Info on the teach pendant.

      check version 1
    2. Check Controller type and Controller software.

      check version 2

Download Robot Software

Visit the official website of DENSO robotics on the IPC, and download and install the robot software WINCAPSⅢ as prompted. After you install WINCAPSⅢ, double-click WINCAPSⅢ to open the software.

Set up the Network Connection

  1. Plug the Ethernet cable into the controller’s Ethernet interface to connect the IPC and the robot controller.

  2. Check the robot’s IP address and make sure it is on the same subnet as the IPC.

    Click here for instructions
    1. On the teach pendant, tap Setting  Communication and Token  Network and Permission .

      check robot ip 1
    2. In the Communicate Settings window, select Ethernet in the Device area, and view the IP Address and Subnet mask in the Setting area.

      check robot ip 2
  3. If the IP addresses of the robot and the IPC are in different subnets, modify the IPC’s IP address.

Obtain Control of the Robot

After completing configurations of this section, Mech-Mind Vision System will gain control of the robot and will be able to master-control the robot.

Modify Robot Program (Only required by RC9 controller)

By default, the programs provided by Mech-Vision and Mech-Viz only support the RC8 controller. If you are using an RC9 controller, please modify the program files according to the instructions below.

  1. On the IPC, go to Communication Component\Robot_Server\src\robot\denso from the installation directory of Mech-Vision & Mech-Viz, and you will see the following files:

    • __init__

    • cao_controller

    • denso_robot

    • denso_robot_adapter

  2. Open the denso_robot_adapter file, change RC8 to RC9, and save the modification.

    denso robot adapter
  3. Open the cao_controller file, change RC8 to RC9, and save the modification.

    cao controller

Transfer Robot Control

Please transfer the robot control to Mech-Viz according to the instructions below.

  1. Tap Settings  Communication and Start Control  Start Control on the teach pendant.

  2. In the Start Control Settings window, change the IP address of Ethernet1 to the IPC’s IP address.

  3. Turn the mode key of the teach pendant to the automatic mode to later test the master-control communication between the robot and IPC.

Test the Master-Control Communication

For more information, see Test Robot Connection.

  1. After Mech-Viz successfully established master-control communication with the robot, the velocity of the robot shown on the teach pendant will be reset to 100%. To ensure safety, remember to reduce the velocity on the teach pendant.

  2. In the scenario where Mech-Mind Vision System master-controls a DENSO robot, after Sync Robot is executed in Mech-Viz, the joint positions of the simulating robot in Mech-Viz might all be updated to 0. To resolve this issue, disconnect the master-control communication on Mech-Viz, and then reconnect it.