Communication Protocol

You are viewing an old version of the documentation. You can switch to the documentation of the latest version by clicking the top-right corner of the page.

From Mech-Center to PLC

Control_Output

Bit Data

7

/

6

/

5

/

4

Command execution complete (Bool)

3

Data ready (Bool)

2

Camera capturing complete (Bool)

1

Trigger acknowledge (Bool)

0

Heartbeat (Bool)

Command_Complete

This module indicates that the execution of a command has been completed, and the data returned by the command can be read. For commands 102 and 205, only when the last byte of data has been sent will this module’s signal be set to 1.

Data_Ready

This module indicates that new data has been sent, and the PLC can read the data. This module’s signal is dedicated for command 102 or command 205 when multiple sets of robot pose data are expected.

Exposure_Complete

When the camera completes image capturing, this module’s signal is set to 1. This module is used to indicate whether the object can be moved, or whether the robot in an eye-in-hand application can move from the image-capturing position.

Trigger_Acknowledge

Trigger Acknowledge = 1 means that the vision system has been triggered successfully by the Trigger signal. Tigger Acknowledge will stay at 1 until the Trigger signal is reset to 0.

Heartbeat

System heartbeat that flips every 1 second.

Status_Code

The status code, INT32.

The execution status code sent by the vision system to indicate normal and erroneous statuses.

Calib_Cam_Status

Calibration status, INT8.

This module’s signal is dedicated for command 701. 0: The calibration is in progress. 1: The calibration is completed.

Send_Pose_Num

The number of sent poses, INT8. The number of poses sent this time of command execution.

Visual_Point_Index

The position of the “Vision Move” waypoint in the entire planned path. The “Vision Move” waypoint is the one where the robot performs picking.

For example, if the path is composed of Steps Fixed-Point Move_1, Fixed-Point Move_2, Vision Move, “Fixed-Point Move_3” sequentially, the position of “Vision Move” is 3.

If the path does not contain any “Vision Move”, the value of this parameter is 0.

Data type: INT8

DO_List

The 64 INT8 DO signals for controlling multiple suction cup sections or array grippers.

Byte Bit 0-7

0

DO list 0: signals 0 to 7

1

DO list 1: signals 8 to 15

2

DO list 2: signals 16 to 23

3

DO list 3: signals 24 to 31

4

DO list 4: signals 32 to 39

5

DO list 5: signals 40 to 47

6

DO list 6: signals 48 to 55

7

DO list 7: signals 56 to 63

Notify_Message

The customized message sent by the “Notify” Step of the Mech-Viz / Mech-Vision project.

The message should be an integer, INT32.

Send_Pose_Type

The type of sent poses, INT8.

  • 1: joint positions.

  • 2: TCP.

Target_Pose

The robot poses of the waypoints in the form of joint positions or TCP.

The data from this module should be divided by 10000 before use.

A TCP contains Cartesian coordinates and Euler angles:

X, Y, Z, A, B, C

A set of joint positions contains at most 6 joint angles:

J1, J2, J3, J4, J5, J6

Byte Bit 0-7

0 to 3

X or J1, INT32

4 to 7

Y or J2, INT32

8 to 11

Z or J3, INT32

12 to 15

A or J4, INT32

16 to 19

B or J5, INT32

20 to 23

C or J6, INT32

Target_Label

The labels corresponding to the sent poses. The values should be non-negative integers.

Data type: INT32

Target_Speed

The velocity percentage values of the waypoints from the move-type Steps. Range: 0 to 100

Data type: INT32

Ext_Output_Data

Reserved module for transmitting other data.

This module takes up 40 bytes (INT32[1: 10], 10 INT32 integers in total).

From PLC to Mech-Center

Control_Input

Bit Data

7

/

6

/

5

/

4

Reset Notify (Bool)

3

Data Acknowledge (Bool)

2

Reset Exposure_Complete (Bool)

1

Trigger (Bool)

0

Comm Enable (Bool)

Reset_Exposure

Reset Exposure_Complete (Bool)

If Reset_Exposure = 1, Exposure Complete will be set to 0.

Data_Acknowledge

Data_Acknowledge is used for acknowledging that the data returned by command 102 or command 205 has been read.

If Data_Acknowledge = 0, the PLC has not read the data from Mech-Center and the data are kept at the port.

If Data_Acknowledge = 1, the PLC has read the data from Mech-Center and Mech-Center can write the data of the next round.

Data_Acknowledge can be reset at heartbeat flip or when Data_Ready = 0.

Reset_Notify

Reset Notify (Bool)

If Reset Notify = 1, the content of Notify_Message will be cleared.

Trigger

Trigger (Bool)

If Trigger = 1, Mech-Center will read the sent command and execute it.

Trigger Acknowledge can be reset once Mech-Center receives the Trigger signal.

The upward segment of the signal is considered as 1.

Comm_Enable

Comm Enable (Bool)

0: Communication disabled. Mech-Center will ignore the Trigger signal.

1: Communication enabled. The Trigger signal will work and Mech-Center will receive commands.

Command

Command code, INT32.

Calib_Rob_Status

  • 0: The calibration starts.

  • 1: The robot has moved to the last calibration point sent.

  • 2: The robot failed to move to the last calibration point sent.

Data type: INT8

Vision_Proj_Num

Mech-Vision project ID, which can be viewed before the project name in the Project List panel in Mech-Vision.

Data type: INT8

Vision_Recipe_Num

The ID of the parameter recipe in the Mech-Vision project. The ID is a positive integer in the range of 1 to 99. To view the parameter recipe ID, in the lower right of Mech-Vision, click menu:Project Assistant[Parameter Recipe].

Data type: INT8

Viz_Task_Name

The Step ID of the Mech-Viz Step involved. The Step ID can be viewed in the parameters of the Step.

Data type: INT8

Viz_Task_Value

The exit port number of the Mech-Viz “Branch by Msg” Step, or the value set to the Current Index parameter of a Mech-Viz Step.

Data type: INT8

Req_Pose_Num

The number of vision points to be requested from Mech-Vision.

0: Request all available vision points in the vision result of Mech-Vision.

Data type: INT8

Robot_Pose_Type

Type of robot pose to be sent.

Data type: INT8

Req_Pose_Type

Expected type of waypoint pose to be returned from Mech-Viz.

  • 1: joint positions.

  • 2: TCP.

Data type: INT8

Robot_Pose_JPS

Robot joint positions to be sent to Mech-Vision / Mech-Viz.

Please multiply the joint position data by 10000 before setting it to the module.

A set of joint positions contains at most 6 joint angles (6 INT32 integers):

Byte Bit 0-7

0 to 3

Robot J1 joint angle, INT32

4 to 7

Robot J2 joint angle, INT32

8 to 11

Robot J3 joint angle, INT32

12 to 15

Robot J4 joint angle, INT32

16 to 19

Robot J5 joint angle, INT32

20 to 23

Robot J6 joint angle, INT32

Robot_Pose_TCP

The current robot flange pose to be sent to Mech-Vision / Mech-Viz.

Please multiply the pose data by 10000 before setting it to the module.

A flange pose contains Cartesian coordinates (X, Y, Z) and Euler angles (A, B, C), 6 INT32 integers in total.

Byte Bit 0-7

0 to 3

X of current robot flange pose, INT32

4 to 7

Y of current robot flange pose, INT32

8 to 11

Z of current robot flange pose, INT32

12 to 15

A of current robot flange pose, INT32

16 to 19

B of current robot flange pose, INT32

20 to 23

C of current robot flange pose, INT32

Ext_Input_Data

Reserved module for transmitting other data.