Mech-Vision Project Unregistered (Error: 1001)

You are viewing an old version of the documentation. You can switch to the documentation of the latest version by clicking the top-right corner of the page.

Symptom:

When triggering the Mech-Vision project to run using the Standard Interface, even if the “Autoload Solution” option has been checked for the project, the log displayed “Unregistered” or “Project is empty. Please make sure the autoload project is set”.

Affected Versions:

All versions.

Possible Causes:

  1. The "Procedure Out" Step was not added in the Mech-Vision project.

  2. Mech-Vision was in the Developer mode and the same project or solution was opened in multiple software.

  3. The communication component (Communication Component) was interrupted, paused, or blocked due to an exception.

Solution:

  1. Add a "Procedure Out" Step in the Mech-Vision project.

  2. Go to Settings > Options in Mech-Vision, and disable the “Developer mode”.

  3. Open the Task Manager and check if the following program is running in the background. Right-click on it, then click End task and finally restart the software.

    alt